Build 12014 (19.2.2020):

  • New Monitor serial numbers: Depending on the manufacturer, these are now also read out via WMI. To force the reading of serial numbers via WMI, the new switch “//WmiMonitors 1” can be used
  • Important Significant optimization of loading times for user-related queries on effective user rights
  • Database tables are created correctly if the database has been created previously and then Verify is clicked
  • Tasks: Use of newly created reports (when saving or as mail attachments) also possible without restarting Automation Service
  • Tasks: When creating new tasks, the option “Row.Count >0” is set by default
  • Query Editor: Selection of paths between the tables is saved even after editing a query again
  • Improvement in the calculation of effective user rights (Builtin\Users is resolved correctly)
  • Exchange acquisition: Increase the reliability of acquisition even on machines with strict Powershell Execution Policy
  • SQL Server acquisition: More useful return code when using Windows credentials and SQL Server is not present
  • License management: If devices that have been assigned a device license are archived, the corresponding licenses are also archived correctly and remain connected to the device.
  • File search: If certain files are no longer found during a renewed file search, only the actually existing results are listed -> the results are no longer cumulated
  • Detection of SNMP devices: The community “public” is no longer automatically used as fallback, but only if it has been explicitly assigned to the scan definition
  • Custom properties: It is now possible to create up to 15 different custom properties of type “Boolean” for Devices instead of 5
  • Microsoft365 acquisition: now all accounts, not only the first 100 are read
  • Microsoft365 acquisition: improved error message for incorrect data entry
  • Exchange acquisition: The value ResourceType is renamed to MailboxType and read again correctly (Attention During the migration all mailbox data is deleted and must be captured again afterwards).
  • Exchange acquisition: Correct display of linked mailboxes
  • Exchange acquisition: New value: SmtpAddress
  • Dynamic documents: Connection of external database works correctly again
  • MAC address table: The interface alias is displayed for each interface and port

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.